| Class | check_prog_vars | 
| In: | util/check_prog_vars.f90 | 
Note that Japanese and English are described in parallel.
予報変数の値の確認
Check values of prognostic variables
| !$ ! SurfaceFlux : | 地表面フラックスの計算 | 
| !$ ! SurfaceFluxOutput : | 地表面フラックスの出力 | 
| !$ ! ———— : | ———— | 
| !$ ! SurfaceFlux : | Calculate surface fluxes | 
| !$ ! SurfaceFluxOutput : | Output surface fluxes | 
| Subroutine : | |||
| xy_Ps(0:imax-1, 1:jmax) : | real(DP), intent(in) 
 | ||
| xyz_U(0:imax-1, 1:jmax, 1:kmax) : | real(DP), intent(in) 
 | ||
| xyz_V(0:imax-1, 1:jmax, 1:kmax) : | real(DP), intent(in) 
 | ||
| xyz_Temp(0:imax-1, 1:jmax, 1:kmax) : | real(DP), intent(in) 
 | ||
| xyzf_QMix(0:imax-1, 1:jmax, 1:kmax, 1:ncmax) : | real(DP), intent(in) 
 | 
予報変数の値の確認
Check values of prognostic variables
  subroutine CheckProgVars( xy_Ps, xyz_U, xyz_V, xyz_Temp, xyzf_QMix )
    !
    ! 予報変数の値の確認
    !
    ! Check values of prognostic variables
    !
    ! モジュール引用 ; USE statements
    !
    ! 格子点設定
    ! Grid points settings
    !
    use gridset, only: imax, jmax, kmax    ! 鉛直層数. 
                               ! Number of vertical level
    ! 組成に関わる配列の設定
    ! Settings of array for atmospheric composition
    !
    use composition, only: ncmax, IndexH2OVap
    ! メッセージ出力
    ! Message output
    !
    use dc_message, only: MessageNotify
    ! 時刻管理
    ! Time control
    !
    use timeset, only: TimeN, TimesetClockStart, TimesetClockStop
    ! デバッグ用ユーティリティ
    ! Utilities for debug
    !
    use dc_trace, only: DbgMessage, BeginSub, EndSub
    ! 宣言文 ; Declaration statements
    !
    implicit none
    real(DP), intent(in):: xy_Ps (0:imax-1, 1:jmax)
                              ! $ p_s (t-\Delta t) $ . 地表面気圧. Surface pressure (Pa)
    real(DP), intent(in):: xyz_U (0:imax-1, 1:jmax, 1:kmax)
                              ! $ u $ . 東西風速. Eastward wind
    real(DP), intent(in):: xyz_V (0:imax-1, 1:jmax, 1:kmax)
                              ! $ v $ . 南北風速. Northward wind
    real(DP), intent(in):: xyz_Temp (0:imax-1, 1:jmax, 1:kmax)
                              ! $ T $ . 温度 (整数レベル). 
                              ! Temperature (full level)
    real(DP), intent(in):: xyzf_QMix(0:imax-1, 1:jmax, 1:kmax, 1:ncmax)
                              ! $ q $ .     比湿. Specific humidity
    ! 作業変数
    ! Work variables
    !
    integer:: i               ! 経度方向に回る DO ループ用作業変数
                              ! Work variables for DO loop in longitude
    integer:: j               ! 緯度方向に回る DO ループ用作業変数
                              ! Work variables for DO loop in latitude
    integer:: k               ! 鉛直方向に回る DO ループ用作業変数
                              ! Work variables for DO loop in vertical direction
    integer:: n               ! 組成方向に回る DO ループ用作業変数
                              ! Work variables for DO loop in dimension of constituents
    real(DP) :: minval, maxval
    integer  :: mini, minj, mink
    integer  :: maxi, maxj, maxk
    ! 実行文 ; Executable statement
    !
    ! 計算時間計測開始
    ! Start measurement of computation time
    !
    call TimesetClockStart( module_name )
    ! 初期化
    ! Initialization
    !
    if ( .not. check_prog_vars_inited ) call CheckProgVarsInit
    i = 0
    j = 1
    k = 1
    minval = xyz_U(i,j,k)
    maxval = xyz_U(i,j,k)
    mini   = i
    minj   = j
    mink   = k
    maxi   = i
    maxj   = j
    maxk   = k
    do k = 1, kmax
      do j = 1, jmax
        do i = 0, imax-1
          if ( xyz_U   (i,j,k) < minval ) then
            minval = xyz_U   (i,j,k)
            mini   = i
            minj   = j
            mink   = k
          end if
          if ( maxval < xyz_U   (i,j,k) ) then
            maxval = xyz_U   (i,j,k)
            maxi   = i
            maxj   = j
            maxk   = k
          end if
        end do
      end do
    end do
    if ( minval  < VelMin  ) then
      call MessageNotify( 'M', module_name, 'Minimum value : U(%d,%d,%d) = %f.', i = (/ mini, minj, mink /), d = (/ minval /) )
    end if
    if ( VelMax  < maxval  ) then
      call MessageNotify( 'M', module_name, 'Maximum value : U(%d,%d,%d) = %f.', i = (/ maxi, maxj, maxk /), d = (/ maxval /) )
    end if
    i = 0
    j = 1
    k = 1
    minval = xyz_V(i,j,k)
    maxval = xyz_V(i,j,k)
    mini   = i
    minj   = j
    mink   = k
    maxi   = i
    maxj   = j
    maxk   = k
    do k = 1, kmax
      do j = 1, jmax
        do i = 0, imax-1
          if ( xyz_V   (i,j,k) < minval ) then
            minval = xyz_V   (i,j,k)
            mini   = i
            minj   = j
            mink   = k
          end if
          if ( maxval < xyz_V   (i,j,k) ) then
            maxval = xyz_V   (i,j,k)
            maxi   = i
            maxj   = j
            maxk   = k
          end if
        end do
      end do
    end do
    if ( minval  < VelMin  ) then
      call MessageNotify( 'M', module_name, 'Minimum value : V(%d,%d,%d) = %f.', i = (/ mini, minj, mink /), d = (/ minval /) )
    end if
    if ( VelMax  < maxval  ) then
      call MessageNotify( 'M', module_name, 'Maximum value : V(%d,%d,%d) = %f.', i = (/ maxi, maxj, maxk /), d = (/ maxval /) )
    end if
    i = 0
    j = 1
    k = 1
    minval = xyz_Temp(i,j,k)
    maxval = xyz_Temp(i,j,k)
    mini   = i
    minj   = j
    mink   = k
    maxi   = i
    maxj   = j
    maxk   = k
    do k = 1, kmax
      do j = 1, jmax
        do i = 0, imax-1
          if ( xyz_Temp(i,j,k) < minval ) then
            minval = xyz_Temp(i,j,k)
            mini   = i
            minj   = j
            mink   = k
          end if
          if ( maxval < xyz_Temp(i,j,k) ) then
            maxval = xyz_Temp(i,j,k)
            maxi   = i
            maxj   = j
            maxk   = k
          end if
        end do
      end do
    end do
    if ( minval  < TempMin ) then
      call MessageNotify( 'M', module_name, 'Minimum value : Temp(%d,%d,%d) = %f.', i = (/ mini, minj, mink /), d = (/ minval /) )
    end if
    if ( TempMax < maxval  ) then
      call MessageNotify( 'M', module_name, 'Maximum value : Temp(%d,%d,%d) = %f.', i = (/ maxi, maxj, maxk /), d = (/ maxval /) )
    end if
    ! ヒストリデータ出力
    ! History data output
    !
    ! 計算時間計測一時停止
    ! Pause measurement of computation time
    !
    call TimesetClockStop( module_name )
  end subroutine CheckProgVars
          | Variable : | |||
| check_prog_vars_inited = .false. : | logical, save, public 
 | 
| Subroutine : | 
check_prog_vars モジュールの初期化を行います. NAMELIST#check_prog_vars_nml の読み込みはこの手続きで行われます.
"check_prog_vars" module is initialized. "NAMELIST#check_prog_vars_nml" is loaded in this procedure.
This procedure input/output NAMELIST#check_prog_vars_nml .
  subroutine CheckProgVarsInit
    !
    ! check_prog_vars モジュールの初期化を行います. 
    ! NAMELIST#check_prog_vars_nml の読み込みはこの手続きで行われます. 
    !
    ! "check_prog_vars" module is initialized. 
    ! "NAMELIST#check_prog_vars_nml" is loaded in this procedure. 
    !
    ! モジュール引用 ; USE statements
    !
    ! NAMELIST ファイル入力に関するユーティリティ
    ! Utilities for NAMELIST file input
    !
    use namelist_util, only: namelist_filename, NmlutilMsg, NmlutilAryValid
    ! ファイル入出力補助
    ! File I/O support
    !
    use dc_iounit, only: FileOpen
    ! 種別型パラメタ
    ! Kind type parameter
    !
    use dc_types, only: STDOUT ! 標準出力の装置番号. Unit number of standard output
    ! 文字列操作
    ! Character handling
    !
    use dc_string, only: StoA
    ! メッセージ出力
    ! Message output
    !
    use dc_message, only: MessageNotify
    ! 宣言文 ; Declaration statements
    !
    implicit none
    integer:: unit_nml        ! NAMELIST ファイルオープン用装置番号. 
                              ! Unit number for NAMELIST file open
    integer:: iostat_nml      ! NAMELIST 読み込み時の IOSTAT. 
                              ! IOSTAT of NAMELIST read
    ! NAMELIST 変数群
    ! NAMELIST group name
    !
    namelist /check_prog_vars_nml/ VelMin, VelMax, TempMin, TempMax
          !
          ! デフォルト値については初期化手続 "check_prog_vars#CheckProgVarsInit" 
          ! のソースコードを参照のこと. 
          !
          ! Refer to source codes in the initialization procedure
          ! "check_prog_vars#CheckProgVarsInit" for the default values. 
          !
    ! 実行文 ; Executable statement
    !
    if ( check_prog_vars_inited ) return
!!$    call InitCheck
    ! デフォルト値の設定
    ! Default values settings
    !
    VelMin  = -300.0_DP
    VelMax  =  300.0_DP
    TempMin =   50.0_DP
    TempMax =  350.0_DP
    ! NAMELIST の読み込み
    ! NAMELIST is input
    !
    if ( trim(namelist_filename) /= '' ) then
      call FileOpen( unit_nml, namelist_filename, mode = 'r' ) ! (in)
      rewind( unit_nml )
      read( unit_nml, nml = check_prog_vars_nml, iostat = iostat_nml )        ! (out)
      close( unit_nml )
      call NmlutilMsg( iostat_nml, module_name ) ! (in)
    end if
    ! 印字 ; Print
    !
    call MessageNotify( 'M', module_name, '----- Initialization Messages -----' )
    call MessageNotify( 'M', module_name, '  VelMin  = %f', d = (/ VelMin  /) )
    call MessageNotify( 'M', module_name, '  VelMax  = %f', d = (/ VelMax  /) )
    call MessageNotify( 'M', module_name, '  TempMin = %f', d = (/ TempMin /) )
    call MessageNotify( 'M', module_name, '  TempMax = %f', d = (/ TempMax /) )
    call MessageNotify( 'M', module_name, '-- version = %c', c1 = trim(version) )
    check_prog_vars_inited = .true.
  end subroutine CheckProgVarsInit
          | Constant : | |||
| module_name = ‘check_prog_vars‘ : | character(*), parameter 
 | 
| Constant : | |||
| version = ’$Name: dcpam5-20110327 $’ // ’$Id: check_prog_vars.f90,v 1.3 2010-10-07 15:34:42 yot Exp $’ : | character(*), parameter 
 |